Taylor 791 Specifications

Specifications

Electrical

One dedicated electrical connection is required. See the Electrical chart for the proper electrical requirements. Manufactured to be cord connected.

Beater Motor

Two, 1.5 HP.

Refrigeration System

One, 9500 BTU/hr compressor (nominal rating). R404A

Separate Hopper Refrigeration (SHR), One, 400 BTU/hr. R134A

(BTUs may vary based on application.)

Air Cooled

Minimum 3” around all sides. Minimum air clearances must be met to assure adequate air flow for optimum performance.

Water Cooled

Water inlet and drain connections out of rear 3/8” FPT.

Weights

Lbs.

Kgs.

Net

527

239

Crated

586

265.8

Cu. Ft.

Cu. M.

Volume

47.3

1.34

Dimensions

In.

mm.

Width

20 7/16

519

Depth

33 3/16

843

Height

59 7/8

1521

Floor Clearance

7 ¾

197

*Mounted on standard casters.

Electrical

Total Amps

Supplied with NEMA Cord

208-230/60/1 Air

19

L6-30P

208-230/60/1 Water

19

L6-30P

208-230/60/3 Air

14

L15-20P

208-230/60/3 Water

14

L15-20P