Danfoss mix hopper compressor for Taylor soft serve machines. Direct replacement for Taylor part numbers 047701-27 and X47701SER2. Cools the ingredient mix in the hopper refrigeration circuit. 208–230V. Fits Taylor 60, 62, 162, 168, 336–339, 441, 444, 702, 741, 750, 751, 754, 772, 774, 791, 793, 794, 8751, 8752, 8754, C712, and C713. Ships same day.

Limited Quantity In Stock

Taylor 047701-27 / X47701SER2 Mix Hopper Compressor – Danfoss, 208/230V

This Danfoss compressor is the refrigeration unit responsible for cooling the mix in the hopper of a wide range of Taylor soft serve machines. It operates on 208–230V and is a direct replacement for Taylor part numbers 047701-27 and X47701SER2.

Key Features

  • Danfoss mix hopper compressor — cools ingredient mix in the hopper refrigeration circuit
  • Direct replacement for Taylor part numbers 047701-27 and X47701SER2
  • 208–230V operation
  • Fits 15+ Taylor soft serve and shake machine models
  • Made in the USA
  • In stock — ships same day if ordered by 6:00 PM EST on weekdays

How the Mix Hopper Refrigeration System Works

This Danfoss compressor only cools the mix in the hopper — it is a separate refrigeration circuit from the freezing cylinder. The refrigeration system includes this compressor, an EPR valve (evaporator pressure regulator), and a fixed orifice metering device (capillary tube). The mix hopper condenser fan motor is wired in series with the compressor. The power board supplies 208–230V power directly to the compressor.

How to Diagnose a Bad Mix Hopper Compressor

Since this compressor only cools the mix hopper, the first symptom of failure is elevated mix temperature in the hopper. Here is how the diagnostic chain works:

  • The thermistor probe reads mix temperature in the hopper and reports to the logic board
  • The logic board signals the power board to supply power to the compressor
  • A ribbon cable connects the logic board to the power board
  • If the compressor is shorted, it can damage the power board — always inspect the power board when replacing this compressor
  • If the mix hopper condenser fan is not running, the compressor will not run (wired in series)

Common failure signs: mix hopper temperature alarm, warm or semi-frozen mix in the hopper, compressor not starting or cycling off on thermal overload.

Compatible Taylor Machine Models

Fits Taylor models: 60, 62, 162, 168, 336, 337, 338, 339, 441, 444, 702, 741, 750, 751, 754, 772, 774, 791, 793 (Chick-fil-A), 794, 8751, 8752, 8754, C712, C713.

Specifications

  • Part Numbers: 047701-27 / X47701SER2
  • Manufacturer: Danfoss
  • Voltage: 208–230V
  • Country of Origin: USA
  • HS Code: 8419990060
  • Dimensions: 10" L × 8" W × 8" H
  • Weight: 19 lbs

Ships same day if ordered by 6:00 PM EST on weekdays. No inflated shipping charges. Questions about this compressor or your machine? Call us at 800-879-7839.

Part Numbers: 047701-27 / X47701SER2 Manufacturer: Danfoss Voltage: 208–230V Country of Origin: USA HS Code: 8419990060 Dimensions: 10" L x 8" W x 8" H Weight: 19 lbs
Please see our Shipping Policy for more information